CONDUCTIVE LEVEL CONTROL

 

CL-1 - Conductivity level relay

Conductivity level relay
Mod. CL-1

  • Monitor the presence or absence of liquid detecting the conductivity between one of the electrode and the metallic tank wall
  • Sensitivy from 0-500Ω to 0-250KΩ
  • Trimmer for sensitivity adjustment and relays delay
  • Output: 2 SPDT contacts
  • Power supply: 24Vac/dc

    Replace LC11 and RAL11 instrument
Datasheet

CL-2 - Two independent channels conductivity level relay

Two independent channels conductivity level relay
Mod. CL-2

  • Monitor the presence or absence of liquid detecting the conductivity between one of the electrode and the metallic tank wall
  • Sensitivity from 0-500Ω to 0-250KΩ
  • Trimmer for sensibility adjustment and relays delay
  • Output: 2 SPDT contacts (1 relay per level electrode)
  • Standard power supply: 24Vac/dc or 110-230Vac

    Replace LC02 and RAL04 instrument
Datasheet

CL-S - Conductivity level relay with cable safety alarm

Conductivity level relay with cable safety alarm
Mod. CL-S

  • Monitor the presence or absence of liquid detecting the conductivity between one of the electrode and the metallic tank wall
  • Sensitivity from 0-500Ω to 0-150KΩ
  • Internal circuits detects constantly the electrical connection to the electrodes
  • Trimmer for sensibility adjustment and relay delay
  • Output: 2 SPDT contacts (1 relay for level + 1 relay for cable alarm)
  • Power supply 24Vac/dc

    Replace LC12 and RAL12 instrument
Datasheet

SLFK - Coated-electrode level probe with fixed immersion

Coated-electrode level probe with fixed immersion
Mod. SLFK

  • AISI316L ø4mm electrode shielded with irradiated polyvinylidene fluoride shrink sheat
  • AISI316L + PTFE compression joint
  • Standard electrode length: 175, 275, 500, 750, 1000 mm
  • Installation attachment: 1/4", 3/8", 1/2" BSP male
Datasheet

SLFN - Electrode level probe with fixed immersion

Electrode level probe with fixed immersion
Mod. SLFN

  • AISI316L ø4mm electrode
  • AISI316L + PTFE compression joint
  • Standard electrode length: 114, 125 mm
  • Installation attachment: 1/4", 3/8", 1/2" BSP male
Datasheet

SLR - Coated-electrode level probe with adjustable immersion

Coated-electrode level probe with adjustable immersion
Mod. SLR

  • AISI316L ø5mm electrode shielded with irradiated polyvinylidene fluoride shrink sheat
  • AISI316L + PTFE compression joint
  • Standard electrode length: 290, 500, 750, 1000, 1400, 1800 mm
  • Installation attachment: 1/4", 3/8", 1/2" BSP male
Datasheet